-40%
HANTEK 2D82AUTO 80MHz 4 in 1 Digital Vehicle Diagnostic Oscilloscope Multimeter
$ 131.47
- Description
- Size Guide
Description
An all-new handheld oscilloscope-Hantek2000 series, it continues the compact and lightweight concept but with a new generation of 4 in 1 multifunction tester: Automotive Diagnostic, oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.Important note:
1,we are not responsible for your custom issue( clearing custom and paying TAX), It is out of our countrol. you need to have your VAT number to clear custom by your self. otherwie,please don't make purchasing! Thanks!
2, The package dones't come with 1860 batteries for the easy shipment. Please purchase it in you local.
Package: see below
An all-new handheld oscilloscope-Hantek2000 series, it continues the compact and lightweight concept but with a new generation of 4 in 1 multifunction tester: Automotive Diagnostic, oscilloscope, signal source and multimeter; A small volume of the non-profit grip by a single hand; The suspendingstand was designed to support multi-angle adjustment; Ultra-low-power, Type C charging interface, each 2 hours battery charge allow working one full day or standbytwo months; High-definition color LCD screen display clear and delicate; Minimalist keyboard design simplifyoperation, easy to use.
Overview
With more than 80 kinds of car testing, and scan the QR code on the back of device can open video help files to show you how to test vehicles.
First test projects:
intake manifold vacuum degree & ignition, lampblack adjustment valve vacuum degree & ignition, exhaust ignition (idle), exhaust ignition (start).
Start & Charge:
Charging circuit, current and voltage.
Actuator:
Gasoline / Diesel.
Bus Detection:
CAN bus data observation, CAN bus signal integrity, CAN bus LH long-term acquisition, LIN bus.
Sensors:
air flow meter, camshaft, crankshaft, distributor, lambda sensor, throttle position. . .
Ignition:
Primary/Secondary.
Oscilloscope:
2 channels oscilloscope, 80MHz bandwidth, 250M sampling rate.
Universal multimeter function:
voltage, current, resistance, diode, capacitor, on-off test;
Waveform generator output function
:
output sine, square, triangle, trapezoidal and other waveforms; sine up to 25MHz;
Parameters
Vehicle Testing Mode
Vehicle Diagnosis
Vehicle Diagnostic Function
Ignition
Primary Ignition (Voltage)
Primary Ignition(current)
Primary Ignition(Voltage& Current)
Primary Ignition (Crankshaft Senser)
Primary Ignition&SecondaryIgnition
Secondary
Secondary Ignition Distributor Type (Plug Lead)
Secondary Ignition Distributor Type (King Lead)
Secondary DIS (Positive-fired)
Secondary DIS or CPC (Negative-fired))
Secondary Coil Output Diagnosis
Secondary Ignition&Primary Ignition
Sensors
Air Flow Meter
Air Flow Meter (Hot Wire)
Air Flow Meter (Air Vane)
Air FlowSensor (BOSCH Diesel)
Air Intake PressureSensor (BOSCH Diesel)
Camshaft
Camshaft (Inductive)
Camshaft (AC Excited)
Camshaft (Hall Effect)
Camshaft (BOSCH Common Rail Diesel)
Crankshaft
Crankshaft Inductive Running
Crankshaft Inductive Cranking
Crankshaft Hall Effect
Crankshaft Sensor &Primary Ignition
Distributor
Distributor Pick-up (Hall Effect)
Distributor Inductive Pick-up Cranking
Distributor Inductive Pick-up Running
Lambda Sensors
Lambda Sensor Titania
Lambda Sensor Zirconia
Lambda Sensor Zirconia Pre & Post cat
Throttle Position
Throttle Position Potentiometer
Throttle Position Switch
Throttle Pedal Switch (Bosch Diesel)
ABS Digital Speed Sensor
ABS Analog Speed Sensor
Coolant Temperature (5V)
Coolant Temperature (GM/Vauxhall Simtec
Crash Sensor
MAP Analog
MAP Digital
Hall Effect Road Speed Sensor
Accelerator Pedal (Bosch Diesel)
Bus Diagnosis
CAN Bus
CAN Bus Data View
CAN Bus Signal Integrity
CAN Bus LH Long Capture
LIN Bus
LIN Bus
Engine
Petrol
Single-point Injector (Voltage)
Single-point Injector (Current)
Multi-point Injector (Voltage)
Multi-point Injector (Current)
Injector Voltage & Current
Injector Current & Primary Ignition
Diesel
Common Rail Diesel (Current)
Injector Bosch CDi 3 (Current)
Injector Bosch Diesel (Idling)
Injector Bosch Diesel (Accelerating)
Diesel Glow Plugs
Electronic Fuel Pump
Carbon Canister Solenoid Valve
ERG Recirculation Solenoid Valve
Stepper Motor Example 1
Stepper Motor Example 2
Idle Speed Control Valve (Rotary)
Idle Speed Control Valve (Electromagmetic)
Throttle Servomotor (Idling)
Throttle Servomotor (Accelerating)
Bosch CDi3 Quantity Control Valve
Bosch CDi3 Pressure Regulator Valve
Variable-Speed Cooling Fan On
Variable-Speed Cooling Fan Off
Variable Camshaft Valve Timing
Startup & Charge
Charging Circuits
Charging Circuits Current/Voltage
Charging Circuits Current/Voltage Starting 24V
Charging Circuits Current/Voltage Idling 24V
Charging Circuits Alternator AC Ripple/Diode Diagnosis
Relative Compression Petrol
Relative Compression Diesel
Starting Voltage Drop
Oscilloscope Mode
Bandwidth
80MHz
Channel
2CH+DMM+AWG
Horizontal
Sample Rate Range
250MSa/s(Single-channel), 125MSa/s(Dual-channel)
Waveform Interpolation
(sin x)/x
Record Length
3K samples per dual-channel
SEC/DIV Range
5ns/div~500s/div 1, 2, 5 sequence
Vertical
A/D Converter
8-bit resolution,each channel sampled simultaneously
VOLTS/DIV Range
10mV/div~10V/divat input BNC
Bandwidth Limit, typical
20MHz
Low Frequency Response (-3db)
≤10Hz at BNC
Rise Time at BNC, typical
≤5ns
DC Gain Accuracy
±3% for Normal or Average acquisition mode, 10V/div to 10mV/div
Note: Bandwidth reduced to 6MHz when using a 1X probe.
Acquisition
Acquisition Modes
Normal
Trigger
Type
Edge
Mode
Auto, Normal, single
Level
±4 divisions from center of screen
Trigger Level Accuracy
0.2div × volts/div within ±4 divisions from center of screen
Slope
Rising, Falling, Rising & Falling
Source
CH1/CH2
Input
Coupling
DC, AC or GND
Input Impedance,
25pF±3 pF, 1MΩ±2%
DC coupled
Probe Attenuation
1X, 10X
Supported Probe Attenuation Factors
1X, 10X, 100X, 1000X
Maximum Input Voltage
150V
RMS
Measurement
Cursor
Voltage difference between cursors:
△
V
Time difference between cursors:
△
T
Automatic Measurements
Frequency, Amplitude
Arbitrary Waveform Generator Mode
Waveform Frequency
Sine: 1Hz~25MHz
Square: 1Hz~10MHz
Ramp: 1Hz~1MHz
EXP: 1Hz~5MHz
Sampling
250MSa/s
Amplitude
2.5Vpp(50Ω)
5Vpp(High impedance)
Frequency Resolution
0.001
Channel
1CH waveform output
Waveform Depth
512Sa
Vertical Resolution
12 bit
Frequency Stability
<30ppm
Output Impedance
50 Ω
DMM Testing Modes
Maximum Resolution
4000 Counts
DMM Testing Modes
Voltage,Current,Resistance,Capacitance,Diode &On-Off
Maximum Input Voltage
AC:600V, DC: 800V
Maximum Input Current
AC: 10A, DC:10A
Input Impedance
10MΩ
Measurement Term
Range
Accuracy
Resolution
DC Voltage
400.00mV
± (0.8% + 5)
100uV
4.000V
1mV
40.00V
10mV
400.0V
100mV
600.0V
± (1% + 2)
1V
Overload protection: 400mV: 250V, other: 600Vrms.
AC Voltage
4.000V
± (1.2% + 5)
1mV
40.00V
10mV
400.0V
100mV
600.0V
±(1.5% + 5)
1V
Frequency: 40Hz~400Hz;
Frequency of 400V and 600V: 40Hz~100Hz
DC Current
40.00mA
± (1% + 2)
10uA
200.0mA
± (1.5% + 2)
100uA
4.000A
± (1.8% + 2)
1mA
10.00A
± (3% + 2)
10mA
Overload protection:
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
AC Current
40.00mA
± (1.3% + 2)
10uA
400.0mA
± (1.8% + 2)
100uA
4.000A
± (2% + 3)
1mA
10.00A
± (3% + 5)
10mA
Frequency: 40Hz~400Hz;
self restoring fuse: 200mA/250V, 4A and 10A range no fuse.
Resistance
400.0Ω
±(1% + 3)
0.1Ω
4.000KΩ
±(1.2% + 5)
1Ω
60.00KΩ
10Ω
400.0KΩ
100Ω
4.000MΩ
1KΩ
40.00MΩ
± (1.5%±3)
10KΩ
Overload protection: 220Vrms
Capacitance
40.00nF
±(3% + 5)
10pF
400.0nF
100pF
4.000uF
1nF
40.00uF
10nF
100.0uF
100nF
Overload protection: 220Vrms
Diode
0V~2.0V
On-Off
<50Ω
General Specifications
Display
Display Type
2.8 inch64K color TFT
Display Resolution
320 horizontal by 240 vertical pixels
Display Contrast
Adjustable
Power Supply
Supply Voltage
100V-240VAC, 50Hz-60Hz; DC INPUT: 5VDC, 2A
Power Consumption
<2.5W
Fuse
T, 3A
Battery
2600mA*2
Environmental
Operating Temperature
0~50 °C (32~122 °F)
Storage Temperature
-40~+71 °C (-40~159.8 °F)
Humidity
≤+104
℉
(≤+40°C): ≤90% relative humidity
106
℉
~122
℉
(+41°C ~50°C): ≤60% relative humidity
Cooling Method
Convection
Altitude
Operating and
3,000m (10,000 feet)
Nonoperating
Mechanical Shock
Random Vibration
0.31g
RMS
from 50Hz to 500Hz, 10 minutes on each axis
Nonoperating
2.46g
RMS
from 5Hz to 500Hz, 10 minutes on each axis
Operating
50g, 11ms, half sine
Mechanical
Dimension
199 x 98x 40mm (L x W x H)
Weight
400g
On Jul-12-21 at 02:38:10 PDT, seller added the following information: